Call Us : (404) 474-8715 / (404) IRG-8715

Archive for February, 2013

19
Feb

VFD, AC, DC, & Servo Drive Repair

Service

If you need VFD, AC, DC, & Servo Drive Repair, Industrial Repair Group is your go to partner for dependable service .

Industrial Repair Group performs extensive component level repairs, touching up solder traces, replacing bad components, as well as full testing of ICs, PALs, EPROMs, GALs, surface mounted components and much more. Every VFD, AC, DC, & Servo Drive Repair is subjected to dynamic function tests to verify successful repair and then backed by our 18 month repair guarantee. Sealers and conformal coatings are re-applied as needed with each repair restoring your equipment back to its original OEM specs.

Industrial Repair Group is more than a service provider for your industry. We are a partner and a dedicated resource for your team members to rely upon. Feel confident that we don't play the lingo game. We are real people, with real goals. Our company is always open minded and intent on isolating problems to keep organizations up and running 24/7. We are a leading service provider that believes educated personal is the best policy.

REQUEST A FAST REPAIR QUOTE

Get a Repair Quote

Get a Fast Quote for your VFD, AC, DC, & Servo Drive Repair now by taking a moment to complete an IRG Fast Repair Quote. We will research you product and search our database to return a competitive repair estimate. Industrial Repair Group offers Guaranteed Repairs accompanied with an 18 Month Repair Warranty on All Industrial Repair Services.

Request an Industrial Repair Group Fast Quote

Supported Brands

At Industrial Repair Group, our goal is to offer the best repair in the industry and the most competitive quotes. Our wide selection of services and industry leading 18 month repair guarantee are sure to provide you with the perfect repair solution for all of your industrial needs. We specialize in industrial electronics, electric motor rebuilds, and complete customer satisfaction.

AC TECHNOLOGY INDRAMAT
ACCO BABCOCK INC INDRAMAT & STEGMANN
ACCO BRISTOL INELCO & HS ELECTRONIC
ACCU SORT INEX INC
ACME ELECTRIC & STANDARD POWER INC INLAND MOTOR
ACOPIAN ACRISONS INFRANOR
ACROMAG & MOORE PRODUCTS INGERSOLL RAND
ADEPT TECH INIVEN
ADTECH POWER INC INNOVATIVE TECHNOLOGY INC
ADVANCE BALLAST INTEL
ADVANCED MICRO CONTROLS INTERMEC
ADVANCED MOTION INTERNATIONAL POWER
AEROTECH & MOTOROLA INTROL DESIGN
AGASTAT IRCON
AGILENT ISHIDA
AGR ISI ROBOTICS
AIRCO ISSC
ALLEN BRADLEY ISSC & SCI
AMBITECH IND JOHNSON CONTROLS & YOKOGAWA
AMETEK KTRON
AMGRAPH KTRON & KB ELECTRONICS
AMICON KB ELECTRONICS
AMPROBE KB ELECTRONICS & RIMA
ANAHEIM AUTOMATION KEARNEY & TRECKER
ANALOGIC KEB COMBIVERT
ANDOVER CONTROLSANILAM & SEQUENTIAL INFO SYS KEB COMBIVERT & TOSHIBA
ANORAD KEITHLEY & HOLADAY
ANRITSU KEPCO
AO SMITH & MAGNETEK KEYENCE CORP
APC KIKUSUI
APPLIED AUTOMATION KME INSTACOLOR
APPLIED MATERIAL KNIEL
APPLIED MICORSYSTEMS KOEHLER COMPANY
APV AUTOMATION KONE
APW MCLEAN KONSBERG
ARBURG KRAUSS MAFFEI
ARCAIR KRISTEL CORPORATION
ARCOM LABOD ELECTRONICS
ARGUS LAMBDA
AROS ELECTRONICS LAMBDA & QUALIDYNE CORP
ARPECO LANTECH
ARTESYN TECHNOLOGIES LEESON ELECTRIC CO
ASCO & ITT LEESONA & ELECTRIC REGULATOR
ASEA BROWN BOVERI & STROMBERG LEINE & LINDE
ASHE CONTROLS LENORD & BAUER
ASI CONTROLS LENZE
ASI KEYSTONE & ANALOGIC LEROY SOMER
ASR SERVOTRON LESTER ELECTRIC
ASSOCIATED RESEARCH LEUZE
ASTROSYSTEMS LH RESEARCH
ATC LINCOLN ELECTRIC
ATHENA LITTON
ATLAS LOVE CONTROLS
ATLA COPCO LOVEHOY & BOSTON
AUTOCON TECHNOLGIES INC LOYOLA
AUTOMATED PACKAGING LUST ELECTRONICS
AUTOMATION DIRECT MAGNETEK
AUTOMATION INTELLIGENCE MAGNETEK & GEMCO ELECTRIC
AUTOMATIX MAN ROLAND
AVERY MAPLE SYSTEMS
AVG AUTOMATION MARKEM
AYDON CONTROLS MARQUIP
B & K MARSCH
B & R MAHTSUSHITA ELECTRIC & FANUC
BABCOCK & ASEA BROWN BOVERI MAZAK
BAKER PERKINS MCC ELECTRONICS
BALANCE ENGINEERING MEMOTEC
BALDOR & ASR SERVOTRON MERRICK SCALE
BALWIN & BEI INDUSTRIAL ENCODER METRA INSTRUMENTS
BALL ELECTRONIC METTLER TOLEDO
BALUFF MHI CORRUGATING MACHINERY
BALOGH MIBUDENKI
BANNER ENGINEERING MICRO MEMORY
BARBER COLMAN MICRO MOTION
BARBER COLMAN MICROSWITCH
BARDAC MICROSWITCH & HONEYWELL
BARKSDALE MIKI PULLEY & BOSTON
BARR MULLIN MILLER ELECTRIC
BASLER ELECTRIC & WESTINGHOUSE MILLER ELECTRIC & LINCOLN ELECTRIC
BAUMULLER MINARIK ELECTRIC CO
BEI INDUSTRIAL ENCODER MINARIK ELECTRIC CO & LEESON ELECTRIC CO
BENDIX DYNAPATH MITUSUBISHI
DENDIX SHEFFIELD MOELLER ELECTRIC
BENSHAW MOOG
BENTLEY NEVADA MONTWILL& SCHAFER
BERGER LAHR MOTOROLA
BEST POWER MOTORLA SEMICONDUCTOR
BIKOR CORP MOTORTRONICS
BK PRECISION MSA
BOBST MTS SYSTEMS CO
BOGEN COMMUNICATION MULLER MARTINI & GRAPHA ELECTRONIC
BOMAC MURR ELEKTRONIK
BORG WARNER & DANFOSS NACHI
BOSCH NATIONAL CONTROLS
BOSCHERT & ARTESYN TECHNOLOGIES NEMATRON CORP
BOSTON NEWPORT
BRANSON NEXT
BRIDGEPORT NIKKI DENSO
BURTON & EMERSON NIOBRARA R&D CORP
BUTLER AUTOMATIC NJE CORPORATION
CAROTRON NORDSON
CE INVALCO NORDSON & DANAHER CONTROLS
CHROMALOX NORTH AMERICAN MFG
CINCINNATI MILACRON & ADVANTAGE ELECTRONICS NORTHERN TELECOM
CLEAVELAND MOTION CONTROL NOVA
CONDOR NSD
CONRAC NUM
CONTRAVES NUMERIK
CONTREX OLEC
CONTROL CONCEPTS OKUMA
CONTROL TECHNOLGY INC OMEGA ENGINEERING
COSEL OMRON
COUTANT & LAMBDA OPTO 22
CROMPTON ORIENTAL MOTOR
CROWN ORMEC
CUSTOM SERVO OSG TAP & DIEP&H HARNISCHFEGER
CYBEREX PACKAGE CONTROLS
DANAHER CONTROLS PANALARM
DANAHER MOTION PARKER
DANFOSS & DART CONTROLS PAYNE ENGINEERING & BURTON
DART CONTROLS PEPPERL & FUCHS
DATA ACQUISITION SYS PJILLIPS & PHILLIPS PMA
DAYKIN PHOENIX CONTACT
DAYTRONIC PILZ
DEC PINNACLE SYSTEMS
DELTA PIONEER MAGNETICS
DELTA ELECTRONICS PLANAR SYSTEMS
DELTRON & POWER MATE POLYCOM
DEUTRONIC POLYSPEDE
DIGITEC POWER CONTROL SYSTEM
DISC INSTURMENTS & DANAHER CONTROLS POWER CONVERSION
DISPLAY TECH POWER ELECTRONICS
DOERR POWER GENERAL & WESTINGHOUSE
DOMINO PRINTING POWER MATE
DREXELBROOK POWER ONE
DRIVE CONTROL SYSTEMS POWER PROP
DUNKERMOTOREN POWER SOURCE
DYNAGE & BROWN & SHARPE POWER SWITCH CORP
DYNAMICS RESEARCH POWER SYSTEMS INC
DYNAPOWER & DANAHER CONTROLS POWER VOLT
DYNAPRO & FLUKE POWERTEC INDUSTIRAL MOTORS INC
DYNISCO PULS
EATON CORPORATION PYRAMID
EATON CORPORATION & DANAHER CONTROLS QEST
ECCI QUINDAR ELECTRONICS
EG&G RADIO ENERGIE
ELCIS RAMSEY TECHNOLOGY
ELCO RED LION CONTROLS & SABINA ELECTRIC
ELECTRIC REGULATOR RELIANCE ELECTRIC
ELECTRO CAM RENCO CORP
ELECTRO CRAFT & RELIANCE ELECTRIC ROBICON
ELECTROHOME ROSEMOUNT & WESTINGHOUSE
ELECTROL RTA PAVIA
ELECTROMOTIVE SABINA ELECTRIC
ELECTROSTATICS INC SAFTRONICS
ELGE SANYO
ELO TOUCH SYSTEMS SCHROFF & STYRKONSULT AB
ELPAC & CINCINNATI MILACRON SCI & ISSC
ELSTON ELECTRONICS SELTI
ELWOOD CORPORATION SEMCO
EMS INC SEQUENTIAL INFO SYS
ENCODER PRODUCTS SEW EURODRIVE & TOSHIBA
ETA SHINDENGEN
EUROTHERM CONTROLS SICK OPTIC ELECTRONIC
EXOR SIEMENS
FANUC SIEMENS MOORE
FANUC & GENERAL ELECTRIC SIERRACIN POWER SYSTEMS
FENWAL SIGMA INSTRUMENTS INC
FIFE CORP SMC & CONAIRSOCAPEL
FIREYE & ITT SOLA ELECTRIC
FIRING CIRCUITS SOLITECH
FISCHER & PORTER SONY
FISHER CONTROLS SORENSEN
FLUKE STANDARD POWER INC
FORNEY STATIC CONTROL SYSTEMS
FOXBORO STEGMANN & INDRAMAT
FOXBORO & BALSBAUGH SUMITOMO MACHINERY INC & TOSHIBA
FUJI ELECTRIC SUMTAK CORP
FUTEC SUNX LTD
GAI & ASEA BROWN BOVERI SUPERIOR ELECTRIC
GALIL MOTION CONTROLS SWEO ENGINEERING & ROCHESTER INSTRUMENT SYSTEMS
GD CALIFORNIA INC T&R ELECTRIC & SYRON ENGINEERING
GEM80 TAMAGAWA & RELIANCE ELECTRIC
GENERAL ELECTRIC TAPESWITCH
GENERAL ELECTRIC & FANUC TB WOODS & FUJI ELECTRIC
GIDDINGS & LEWIS TDK
GLENTEK TECNO ELETTRONICA
GOLDSTAR TECTROL
GORING KERR TEIJIN SEIKI
GOSSEN TEKEL
GRAHAM TODD PRODUCTS CORP
GRAINGER TOEI ELECTRIC
GRAPHA ELECTRONIC TOSHIBA
GREAT LAKES INSTRUMENTS TOTKU ELECTRIC & GENERAL ELECTRIC
GROUPE SCHNEIDER TRACO ENGINEERING
HAAS UNICO
HAMMOND UNIPOWER
HATHAWAY VAREC
HAYSEEN VECTOR VID
HEIDELBERG VERO ELECTRONICS & TELEMOTIVE
HEIDENHAIN CORP VIDEO JET
HIRATA VIEW TRONIX
HITACHI & FANUC VIVID
HITRON ELECTRONICS VOLGEN & POWER SOURCE
HOBART BROTHERS CO WARNER ELECTRIC & EMERSON
HOHER AUTOMATION WESTAMP INC & WESTINGHOUSE
HONEYWELL WESTINGHOUSE
HONEYWELL & NEMATRON CORP WHEDCO
HORNER ELECTRIC WIRE ELECTRIC
HUBBELL & FEMCO XENTEK INC
HUBNER & AMICON XYCOM & WARNER ELECTRIC
HURCO MFG CO YASKAWA ELECTRIC
IEE ZENITH
IMMERSION CORPORATION ZYCRON

How AC, DC, Servo Drives Work

Thank you for choosing Industrial Repair Group. If you would like a printable version of How Variable-Frequency Drives Operate, please follow this link: IRG-Variable-Frequency-Drive

How Variable-Frequency Drives Operate

A variable-frequency drive (VFD) is a system for controlling the rotational speed of an alternating current (AC) electric motor by controlling the frequency of the electrical power supplied to the motor.[1][2][3] A variable frequency drive is a specific type of adjustable-speed drive. Variable-frequency drives are also known as adjustable-frequency drives (AFD), variable-speed drives (VSD), AC drives, microdrives or inverter drives. Since the voltage is varied along with frequency, these are sometimes also called VVVF (variable voltage variable frequency) drives.

Variable-frequency drives are widely used. In ventilation systems for large buildings, variable-frequency motors on fans save energy by allowing the volume of air moved to match the system demand. They are also used on pumps, elevator, conveyor and machine tool drives.

VFD types

All VFDs use their output devices (IGBTs, transistors, thyristors) only as switches, turning them only on or off. Using a linear device such as a transistor in its linear mode is impractical for a VFD drive, since the power dissipated in the drive devices would be about as much as the power delivered to the load.

Drives can be classified as:

  • Constant voltage
  • Constant current
  • Cycloconverter

In a constant voltage converter, the intermediate DC link voltage remains approximately constant during each output cycle. In constant current drives, a large inductor is placed between the input rectifier and the output bridge, so the current delivered is nearly constant. A cycloconverter has no input rectifier or DC link and instead connects each output terminal to the appropriate input phase.

The most common type of packaged VF drive is the constant-voltage type, using pulse width modulation to control both the frequency and effective voltage applied to the motor load.

VFD system description

VFD system

A variable frequency drive system generally consists of an AC motor, a controller and an operator interface.[4][5]

VFD motor

The motor used in a VFD system is usually a three-phase induction motor. Some types of single-phase motors can be used, but three-phase motors are usually preferred. Various types of synchronous motors offer advantages in some situations, but induction motors are suitable for most purposes and are generally the most economical choice. Motors that are designed for fixed-speed operation are often used. Certain enhancements to the standard motor designs offer higher reliability and better VFD performance, such as MG-31 rated motors.[6]

VFD controller

Variable frequency drive controllers are solid state electronic power conversion devices. The usual design first converts AC input power to DC intermediate power using a rectifier or converter bridge. The rectifier is usually a three-phase, full-wave-diode bridge. The DC intermediate power is then converted to quasi-sinusoidal AC power using an inverter switching circuit. The inverter circuit is probably the most important section of the VFD, changing DC energy into three channels of AC energy that can be used by an AC motor. These units provide improved power factor, less harmonic distortion, and low sensitivity to the incoming phase sequencing than older phase controlled converter VFD’s. Since incoming power is converted to DC, many units will accept single-phase as well as three-phase input power (acting as a phase converter as well as a speed controller); however the unit must be derated when using single phase input as only part of the rectifier bridge is carrying the connected load.[7]

As new types of semiconductor switches have been introduced, these have promptly been applied to inverter circuits at all voltage and current ratings for which suitable devices are available. Introduced in the 1980s, the insulated-gate bipolar transistor (IGBT) became the device used in most VFD inverter circuits in the first decade of the 21st century.[8][9][10]

AC motor characteristics require the applied voltage to be proportionally adjusted whenever the frequency is changed in order to deliver the rated torque. For example, if a motor is designed to operate at 460 volts at 60 Hz, the applied voltage must be reduced to 230 volts when the frequency is reduced to 30 Hz. Thus the ratio of volts per hertz must be regulated to a constant value (460/60 = 7.67 V/Hz in this case). For optimum performance, some further voltage adjustment may be necessary especially at low speeds, but constant volts per hertz is the general rule. This ratio can be changed in order to change the torque delivered by the motor.[11]

In addition to this simple volts per hertz control more advanced control methods such as vector control and direct torque control (DTC) exist. These methods adjust the motor voltage in such a way that the magnetic flux and mechanical torque of the motor can be precisely controlled.

The usual method used to achieve variable motor voltage is pulse-width modulation (PWM). With PWM voltage control, the inverter switches are used to construct a quasi-sinusoidal output waveform by a series of narrow voltage pulses with pseudosinusoidal varying pulse durations.[8][12]

Operation of the motors above rated name plate speed (base speed) is possible, but is limited to conditions that do not require more power than nameplate rating of the motor. This is sometimes called “field weakening” and, for AC motors, means operating at less than rated volts/hertz and above rated name plate speed. Permanent magnet synchronous motors have quite limited field weakening speed range due to the constant magnet flux linkage. Wound rotor synchronous motors and induction motors have much wider speed range. For example, a 100 hp, 460 V, 60 Hz, 1775 RPM (4 pole) induction motor supplied with 460 V, 75 Hz (6.134 V/Hz), would be limited to 60/75 = 80% torque at 125% speed (2218.75 RPM) = 100% power.[13] At higher speeds the induction motor torque has to be limited further due to the lowering of the breakaway torque of the motor. Thus rated power can be typically produced only up to 130…150 % of the rated name plate speed. Wound rotor synchronous motors can be run even higher speeds. In rolling mill drives often 200…300 % of the base speed is used. Naturally the mechanical strength of the rotor and lifetime of the bearings is also limiting the maximum speed of the motor. It is recommended to consult the motor manufacturer if more than 150 % speed is required by the application.

PWM VFD Output Voltage Waveform

An embedded microprocessor governs the overall operation of the VFD controller. The main microprocessor programming is in firmware that is inaccessible to the VFD user. However, some degree of configuration programming and parameter adjustment is usually provided so that the user can customize the VFD controller to suit specific motor and driven equipment requirements.[8]

VFD operator interface

The operator interface provides a means for an operator to start and stop the motor and adjust the operating speed. Additional operator control functions might include reversing and switching between manual speed adjustment and automatic control from an external process control signal. The operator interface often includes an alphanumeric display and/or indication lights and meters to provide information about the operation of the drive. An operator interface keypad and display unit is often provided on the front of the VFD controller as shown in the photograph above. The keypad display can often be cable-connected and mounted a short distance from the VFD controller. Most are also provided with input and output (I/O) terminals for connecting pushbuttons, switches and other operator interface devices or control signals. A serial communications port is also often available to allow the VFD to be configured, adjusted, monitored and controlled using a computer.[8][14][15]

VFD operation

When an induction motor is connected to a full voltage supply, it draws several times (up to about 6 times) its rated current. As the load accelerates, the available torque usually drops a little and then rises to a peak while the current remains very high until the motor approaches full speed.

By contrast, when a VFD starts a motor, it initially applies a low frequency and voltage to the motor. The starting frequency is typically 2 Hz or less. Thus starting at such a low frequency avoids the high inrush current that occurs when a motor is started by simply applying the utility (mains) voltage by turning on a switch. After the start of the VFD, the applied frequency and voltage are increased at a controlled rate or ramped up to accelerate the load without drawing excessive current. This starting method typically allows a motor to develop 150% of its rated torque while the VFD is drawing less than 50% of its rated current from the mains in the low speed range. A VFD can be adjusted to produce a steady 150% starting torque from standstill right up to full speed.[16] Note, however, that cooling of the motor is usually not good in the low speed range. Thus running at low speeds even with rated torque for long periods is not possible due to overheating of the motor. If continuous operation with high torque is required in low speeds an external fan is usually needed. The manufacturer of the motor and/or the VFD should specify the cooling requirements for this mode of operation.

In principle, the current on the motor side is in direct proportion of the torque that is generated and the voltage on the motor is in direct proportion of the actual speed, while on the network side, the voltage is constant, thus the current on line side is in direct proportion of the power drawn by the motor, that is U.I or C.N where C is torque and N the speed of the motor (we shall consider losses as well, neglected in this explanation).

(1) n stands for network (grid) and m for motor

(2) C stands for torque [Nm], U for voltage [V], I for current [A], and N for speed [rad/s]

We neglect losses for the moment :

Un.In = Um.Im (same power drawn from network and from motor)

Um.Im = Cm.Nm (motor mechanical power = motor electrical power)

Given Un is a constant (network voltage) we conclude : In = Cm.Nm/Un That is “line current (network) is in direct proportion of motor power”.

With a VFD, the stopping sequence is just the opposite as the starting sequence. The frequency and voltage applied to the motor are ramped down at a controlled rate. When the frequency approaches zero, the motor is shut off. A small amount of braking torque is available to help decelerate the load a little faster than it would stop if the motor were simply switched off and allowed to coast. Additional braking torque can be obtained by adding a braking circuit (resistor controlled by a transistor) to dissipate the braking energy. With 4-quadrants rectifiers (active-front-end), the VFD is able to brake the load by applying a reverse torque and reverting the energy back to the network.

Power line harmonics

While PWM allows for nearly sinusoidal currents to be applied to a motor load, the diode rectifier of the VFD takes roughly square-wave current pulses out of the AC grid, creating harmonic distortion in the power line voltage. When the VFD load size is small and the available utility power is large, the effects of VFD systems slicing small chunks out of AC grid generally go unnoticed. Further, in low voltage networks the harmonics caused by single phase equipment such as computers and TVs are such that they are partially cancelled by three-phase diode bridge harmonics.

However, when either a large number of low-current VFDs, or just a few very large-load VFDs are used, they can have a cumulative negative impact on the AC voltages available to other utility customers in the same grid.

When the utility voltage becomes misshapen and distorted the losses in other loads such as normal AC motors are increased. This may in the worst case lead to overheating and shorter operation life. Also substation transformers and compensation capacitors are affected, the latter especially if resonances are aroused by the harmonics.

In order to limit the voltage distortion the owner of the VFDs may be required to install filtering equipment to smooth out the irregular waveform. Alternately, the utility may choose to install filtering equipment of its own at substations affected by the large amount of VFD equipment being used. In high power installations decrease of the harmonics can be obtained by supplying the VSDs from transformers that have different phase shift.[17]

Further, it is possible to use instead of the diode rectifier a similar transistor circuit that is used to control the motor. This kind of rectifier is called active infeed converter in IEC standards. However, manufacturers call it by several names such as active rectifier, ISU (IGBT Supply Unit), AFE (Active Front End) or four quadrant rectifier. With PWM control of the transistors and filter inductors in the supply lines the AC current can be made nearly sinusoidal. Even better attenuation of the harmonics can be obtained by using an LCL (inductor-capacitor-inductor) filter instead of single three-phase filter inductor.

Additional advantage of the active infeed converter over the diode bridge is its ability to feed back the energy from the DC side to the AC grid. Thus no braking resistor is needed and the efficiency of the drive is improved if the drive is frequently required to brake the motor.

Application considerations

The output voltage of a PWM VFD consists of a train of pulses switched at the carrier frequency. Because of the rapid rise time of these pulses, transmission line effects of the cable between the drive and motor must be considered. Since the transmission-line impedance of the cable and motor are different, pulses tend to reflect back from the motor terminals into the cable. The resulting voltages can produce up to twice the rated line voltage for long cable runs, putting high stress on the cable and motor winding and eventual insulation failure. Increasing the cable or motor size/type for long runs and 480v or 600v motors will help offset the stresses imposed upon the equipment due to the VFD (modern 230v single phase motors not effected). At 460 V, the maximum recommended cable distances between VFDs and motors can vary by a factor of 2.5:1. The longer cables distances are allowed at the lower Carrier Switching Frequencies (CSF) of 2.5 kHz. The lower CSF can produce audible noise at the motors. For applications requiring long motor cables VSD manufacturers usually offer du/dt filters that decrease the steepness of the pulses. For very long cables or old motors with insufficient winding insulation more efficient sinus filter is recommended. Expect the older motor’s life to shorten. Purchase VFD rated motors for the application.

Further, the rapid rise time of the pulses may cause trouble with the motor bearings. The stray capacitance of the windings provide paths for high frequency currents that close through the bearings. If the voltage between the shaft and the shield of the motor exceeds few volts the stored charge is discharged as a small spark. Repeated sparking causes erosion in the bearing surface that can be seen as fluting pattern. In order to prevent sparking the motor cable should provide a low impedance return path from the motor frame back to the inverter. Thus it is essential to use a cable designed to be used with VSDs.[18]

In big motors a slip ring with brush can be used to provide a bypass path for the bearing currents. Alternatively isolated bearings can be used.

The 2.5 kHz and 5 kHz CSFs cause fewer motor bearing problems than the 20 kHz CSFs.[19] Shorter cables are recommended at the higher CSF of 20 kHz. The minimum CSF for synchronize tracking of multiple conveyors is 8 kHz.

The high frequency current ripple in the motor cables may also cause interference with other cabling in the building. This is another reason to use a motor cable designed for VSDs that has a symmetrical three-phase structure and good shielding. Further, it is highly recommended to route the motor cables as far away from signal cables as possible.[20]

Available VFD power ratings

Variable frequency drives are available with voltage and current ratings to match the majority of 3-phase motors that are manufactured for operation from utility (mains) power. VFD controllers designed to operate at 111 V to 690 V are often classified as low voltage units. Low voltage units are typically designed for use with motors rated to deliver 0.2 kW or 1/4 horsepower (hp) up to several megawatts. For example, the largest ABB ACS800 single drives are rated for 5.6 MW[21] . Medium voltage VFD controllers are designed to operate at 2,400/4,162 V (60 Hz), 3,000 V (50 Hz) or up to 10 kV. In some applications a step up transformer is placed between a low voltage drive and a medium voltage load. Medium voltage units are typically designed for use with motors rated to deliver 375 kW or 500 hp and above. Medium voltage drives rated above 7 kV and 5,000 or 10,000 hp should probably be considered to be one-of-a-kind (one-off) designs.[22]

Medium voltage drives are generally rated amongst the following voltages : 2,3 KV – 3,3 Kv – 4 Kv – 6 Kv – 11 Kv

The in-between voltages are generally possible as well. The power of MV drives is generally in the range of 0,3 to 100 MW however involving a range a several different type of drives with different technologies.

Dynamic braking

Using the motor as a generator to absorb energy from the system is called dynamic braking. Dynamic braking stops the system more quickly than coasting. Since dynamic braking requires relative motion of the motor’s parts, it becomes less effective at low speed and cannot be used to hold a load at a stopped position. During normal braking of an electric motor the electrical energy produced by the motor is dissipated as heat inside of the rotor, which increases the likelihood of damage and eventual failure. Therefore, some systems transfer this energy to an outside bank of resistors. Cooling fans may be used to protect the resistors from damage. Modern systems have thermal monitoring, so if the temperature of the bank becomes excessive, it will be switched off.[23]

Regenerative variable-frequency drives

Regenerative AC drives have the capacity to recover the braking energy of an overhauling load and return it to the power system.[24]

Line regenerative variable frequency drives, showing capacitors(top cylinders)and inductors attached which filter the regenerated power.

[2][3][24][25][26][27]

Cycloconverters and current-source inverters inherently allow return of energy from the load to the line; voltage-source inverters require an additional converter to return energy to the supply.[28]

Regeneration is only useful in variable-frequency drives where the value of the recovered energy is large compared to the extra cost of a regenerative system,[28] and if the system requires frequent braking and starting. An example would be use in conveyor belt during manufacturing where it should stop for every few minutes, so that the parts can be assembled correctly and moves on. Another example is a crane, where the hoist motor stops and reverses frequently, and braking is required to slow the load during lowering. Regenerative variable-frequency drives are widely used where speed control of overhauling loads is required.

Brushless DC motor drives

Much of the same logic contained in large, powerful VFDs is also embedded in small brushless DC motors such as those commonly used in computer fans. In this case, the chopper usually converts a low DC voltage (such as 12 volts) to the three-phase current used to drive the electromagnets that turn the permanent magnet rotor.

See also

  • Regenerative variable-Frequency drives
  • Direct torque control
  • Frequency changer
  • Space Vector Modulation
  • Variable speed air compressor
  • Vector control (motor)
Category : AC Drive Repair | AC, DC, VFD, Servo Drives | DC Drive Repair | Dexter VFD Repair | Electronic Repair Services | Servo Drive Repair | Spindle Drive Repair | VFD Drive Repair | VFD Drives | Blog
6
Feb

Service

If you need Talaris / DeLaRue & Delta ATM Power Supply Repair, Industrial Repair Group is your go to partner for dependable service.

Talaris DeLaRue Delta Power SupplyIndustrial Repair Group performs extensive component level repairs, touching up solder traces, replacing bad components, as well as full testing of ICs, PALs, EPROMs, GALs, surface mounted components and much more. Every Talaris / DeLaRue & Delta ATM Power Supply Repair is subjected to dynamic function tests to verify successful repair and then backed by our 18 month repair guarantee. Sealers and conformal coatings are re-applied as needed with each repair restoring your equipment back to its original OEM specs.

Industrial Repair Group is more than a service provider for your industry. We are a partner and a dedicated resource for your team members to rely upon. Feel confident that we don't play the lingo game. We are real people, with real goals. Our company is always open minded and intent on isolating problems to keep organizations up and running 24/7. We are a leading service provider that believes educated personal is the best policy.

00013509 78-156-0300

INDUSTRIAL REPAIR GROUP FAST QUOTE

Get a Repair Quote

Get a Fast Quote for your Talaris / DeLaRue & Delta ATM Power Supply Repair now by taking a moment to complete an IRG Fast Repair Quote. We will research you product and search our database to return a competitive repair estimate. Industrial Repair Group offers Guaranteed Repairs accompanied with an 18 Month Repair Warranty on All Industrial Repair Services.

Request an Industrial Repair Group Fast Quote

Supported Brands

At Industrial Repair Group, our goal is to offer the best repair in the industry and the most competitive quotes. Our wide selection of services and industry leading 18 month repair guarantee are sure to provide you with the perfect repair solution for all of your industrial needs. We specialize in industrial electronics, electric motor rebuilds, and complete customer satisfaction.

AC TECHNOLOGY INDRAMAT
ACCO BABCOCK INC INDRAMAT & STEGMANN
ACCO BRISTOL INELCO & HS ELECTRONIC
ACCU SORT INEX INC
ACME ELECTRIC & STANDARD POWER INC INLAND MOTOR
ACOPIAN ACRISONS INFRANOR
ACROMAG & MOORE PRODUCTS INGERSOLL RAND
ADEPT TECH INIVEN
ADTECH POWER INC INNOVATIVE TECHNOLOGY INC
ADVANCE BALLAST INTEL
ADVANCED MICRO CONTROLS INTERMEC
ADVANCED MOTION INTERNATIONAL POWER
AEROTECH & MOTOROLA INTROL DESIGN
AGASTAT IRCON
AGILENT ISHIDA
AGR ISI ROBOTICS
AIRCO ISSC
ALLEN BRADLEY ISSC & SCI
AMBITECH IND JOHNSON CONTROLS & YOKOGAWA
AMETEK KTRON
AMGRAPH KTRON & KB ELECTRONICS
AMICON KB ELECTRONICS
AMPROBE KB ELECTRONICS & RIMA
ANAHEIM AUTOMATION KEARNEY & TRECKER
ANALOGIC KEB COMBIVERT
ANDOVER CONTROLSANILAM & SEQUENTIAL INFO SYS KEB COMBIVERT & TOSHIBA
ANORAD KEITHLEY & HOLADAY
ANRITSU KEPCO
AO SMITH & MAGNETEK KEYENCE CORP
APC KIKUSUI
APPLIED AUTOMATION KME INSTACOLOR
APPLIED MATERIAL KNIEL
APPLIED MICORSYSTEMS KOEHLER COMPANY
APV AUTOMATION KONE
APW MCLEAN KONSBERG
ARBURG KRAUSS MAFFEI
ARCAIR KRISTEL CORPORATION
ARCOM LABOD ELECTRONICS
ARGUS LAMBDA
AROS ELECTRONICS LAMBDA & QUALIDYNE CORP
ARPECO LANTECH
ARTESYN TECHNOLOGIES LEESON ELECTRIC CO
ASCO & ITT LEESONA & ELECTRIC REGULATOR
ASEA BROWN BOVERI & STROMBERG LEINE & LINDE
ASHE CONTROLS LENORD & BAUER
ASI CONTROLS LENZE
ASI KEYSTONE & ANALOGIC LEROY SOMER
ASR SERVOTRON LESTER ELECTRIC
ASSOCIATED RESEARCH LEUZE
ASTROSYSTEMS LH RESEARCH
ATC LINCOLN ELECTRIC
ATHENA LITTON
ATLAS LOVE CONTROLS
ATLA COPCO LOVEHOY & BOSTON
AUTOCON TECHNOLGIES INC LOYOLA
AUTOMATED PACKAGING LUST ELECTRONICS
AUTOMATION DIRECT MAGNETEK
AUTOMATION INTELLIGENCE MAGNETEK & GEMCO ELECTRIC
AUTOMATIX MAN ROLAND
AVERY MAPLE SYSTEMS
AVG AUTOMATION MARKEM
AYDON CONTROLS MARQUIP
B & K MARSCH
B & R MAHTSUSHITA ELECTRIC & FANUC
BABCOCK & ASEA BROWN BOVERI MAZAK
BAKER PERKINS MCC ELECTRONICS
BALANCE ENGINEERING MEMOTEC
BALDOR & ASR SERVOTRON MERRICK SCALE
BALWIN & BEI INDUSTRIAL ENCODER METRA INSTRUMENTS
BALL ELECTRONIC METTLER TOLEDO
BALUFF MHI CORRUGATING MACHINERY
BALOGH MIBUDENKI
BANNER ENGINEERING MICRO MEMORY
BARBER COLMAN MICRO MOTION
BARBER COLMAN MICROSWITCH
BARDAC MICROSWITCH & HONEYWELL
BARKSDALE MIKI PULLEY & BOSTON
BARR MULLIN MILLER ELECTRIC
BASLER ELECTRIC & WESTINGHOUSE MILLER ELECTRIC & LINCOLN ELECTRIC
BAUMULLER MINARIK ELECTRIC CO
BEI INDUSTRIAL ENCODER MINARIK ELECTRIC CO & LEESON ELECTRIC CO
BENDIX DYNAPATH MITUSUBISHI
DENDIX SHEFFIELD MOELLER ELECTRIC
BENSHAW MOOG
BENTLEY NEVADA MONTWILL& SCHAFER
BERGER LAHR MOTOROLA
BEST POWER MOTORLA SEMICONDUCTOR
BIKOR CORP MOTORTRONICS
BK PRECISION MSA
BOBST MTS SYSTEMS CO
BOGEN COMMUNICATION MULLER MARTINI & GRAPHA ELECTRONIC
BOMAC MURR ELEKTRONIK
BORG WARNER & DANFOSS NACHI
BOSCH NATIONAL CONTROLS
BOSCHERT & ARTESYN TECHNOLOGIES NEMATRON CORP
BOSTON NEWPORT
BRANSON NEXT
BRIDGEPORT NIKKI DENSO
BURTON & EMERSON NIOBRARA R&D CORP
BUTLER AUTOMATIC NJE CORPORATION
CAROTRON NORDSON
CE INVALCO NORDSON & DANAHER CONTROLS
CHROMALOX NORTH AMERICAN MFG
CINCINNATI MILACRON & ADVANTAGE ELECTRONICS NORTHERN TELECOM
CLEAVELAND MOTION CONTROL NOVA
CONDOR NSD
CONRAC NUM
CONTRAVES NUMERIK
CONTREX OLEC
CONTROL CONCEPTS OKUMA
CONTROL TECHNOLGY INC OMEGA ENGINEERING
COSEL OMRON
COUTANT & LAMBDA OPTO 22
CROMPTON ORIENTAL MOTOR
CROWN ORMEC
CUSTOM SERVO OSG TAP & DIEP&H HARNISCHFEGER
CYBEREX PACKAGE CONTROLS
DANAHER CONTROLS PANALARM
DANAHER MOTION PARKER
DANFOSS & DART CONTROLS PAYNE ENGINEERING & BURTON
DART CONTROLS PEPPERL & FUCHS
DATA ACQUISITION SYS PJILLIPS & PHILLIPS PMA
DAYKIN PHOENIX CONTACT
DAYTRONIC PILZ
DEC PINNACLE SYSTEMS
DELTA PIONEER MAGNETICS
DELTA ELECTRONICS PLANAR SYSTEMS
DELTRON & POWER MATE POLYCOM
DEUTRONIC POLYSPEDE
DIGITEC POWER CONTROL SYSTEM
DISC INSTURMENTS & DANAHER CONTROLS POWER CONVERSION
DISPLAY TECH POWER ELECTRONICS
DOERR POWER GENERAL & WESTINGHOUSE
DOMINO PRINTING POWER MATE
DREXELBROOK POWER ONE
DRIVE CONTROL SYSTEMS POWER PROP
DUNKERMOTOREN POWER SOURCE
DYNAGE & BROWN & SHARPE POWER SWITCH CORP
DYNAMICS RESEARCH POWER SYSTEMS INC
DYNAPOWER & DANAHER CONTROLS POWER VOLT
DYNAPRO & FLUKE POWERTEC INDUSTIRAL MOTORS INC
DYNISCO PULS
EATON CORPORATION PYRAMID
EATON CORPORATION & DANAHER CONTROLS QEST
ECCI QUINDAR ELECTRONICS
EG&G RADIO ENERGIE
ELCIS RAMSEY TECHNOLOGY
ELCO RED LION CONTROLS & SABINA ELECTRIC
ELECTRIC REGULATOR RELIANCE ELECTRIC
ELECTRO CAM RENCO CORP
ELECTRO CRAFT & RELIANCE ELECTRIC ROBICON
ELECTROHOME ROSEMOUNT & WESTINGHOUSE
ELECTROL RTA PAVIA
ELECTROMOTIVE SABINA ELECTRIC
ELECTROSTATICS INC SAFTRONICS
ELGE SANYO
ELO TOUCH SYSTEMS SCHROFF & STYRKONSULT AB
ELPAC & CINCINNATI MILACRON SCI & ISSC
ELSTON ELECTRONICS SELTI
ELWOOD CORPORATION SEMCO
EMS INC SEQUENTIAL INFO SYS
ENCODER PRODUCTS SEW EURODRIVE & TOSHIBA
ETA SHINDENGEN
EUROTHERM CONTROLS SICK OPTIC ELECTRONIC
EXOR SIEMENS
FANUC SIEMENS MOORE
FANUC & GENERAL ELECTRIC SIERRACIN POWER SYSTEMS
FENWAL SIGMA INSTRUMENTS INC
FIFE CORP SMC & CONAIRSOCAPEL
FIREYE & ITT SOLA ELECTRIC
FIRING CIRCUITS SOLITECH
FISCHER & PORTER SONY
FISHER CONTROLS SORENSEN
FLUKE STANDARD POWER INC
FORNEY STATIC CONTROL SYSTEMS
FOXBORO STEGMANN & INDRAMAT
FOXBORO & BALSBAUGH SUMITOMO MACHINERY INC & TOSHIBA
FUJI ELECTRIC SUMTAK CORP
FUTEC SUNX LTD
GAI & ASEA BROWN BOVERI SUPERIOR ELECTRIC
GALIL MOTION CONTROLS SWEO ENGINEERING & ROCHESTER INSTRUMENT SYSTEMS
GD CALIFORNIA INC T&R ELECTRIC & SYRON ENGINEERING
GEM80 TAMAGAWA & RELIANCE ELECTRIC
GENERAL ELECTRIC TAPESWITCH
GENERAL ELECTRIC & FANUC TB WOODS & FUJI ELECTRIC
GIDDINGS & LEWIS TDK
GLENTEK TECNO ELETTRONICA
GOLDSTAR TECTROL
GORING KERR TEIJIN SEIKI
GOSSEN TEKEL
GRAHAM TODD PRODUCTS CORP
GRAINGER TOEI ELECTRIC
GRAPHA ELECTRONIC TOSHIBA
GREAT LAKES INSTRUMENTS TOTKU ELECTRIC & GENERAL ELECTRIC
GROUPE SCHNEIDER TRACO ENGINEERING
HAAS UNICO
HAMMOND UNIPOWER
HATHAWAY VAREC
HAYSEEN VECTOR VID
HEIDELBERG VERO ELECTRONICS & TELEMOTIVE
HEIDENHAIN CORP VIDEO JET
HIRATA VIEW TRONIX
HITACHI & FANUC VIVID
HITRON ELECTRONICS VOLGEN & POWER SOURCE
HOBART BROTHERS CO WARNER ELECTRIC & EMERSON
HOHER AUTOMATION WESTAMP INC & WESTINGHOUSE
HONEYWELL WESTINGHOUSE
HONEYWELL & NEMATRON CORP WHEDCO
HORNER ELECTRIC WIRE ELECTRIC
HUBBELL & FEMCO XENTEK INC
HUBNER & AMICON XYCOM & WARNER ELECTRIC
HURCO MFG CO YASKAWA ELECTRIC
IEE ZENITH
IMMERSION CORPORATION ZYCRON

How Power Supplies Work

Thank you for choosing Industrial Repair Group. If you would like a printable version of How Power Supplies Operate, please follow this link: IRG-Power-Supply

A power supply is a device that supplies electrical energy to one or more electric loads. The term is most commonly applied to devices that convert one form of electrical energy to another, though it may also refer to devices that convert another form of energy (e.g., mechanical, chemical, solar) to electrical energy. A regulated power supply is one that controls the output voltage or current to a specific value; the controlled value is held nearly constant despite variations in either load current or the voltage supplied by the power supply’s energy source.

Every power supply must obtain the energy it supplies to its load, as well as any energy it consumes while performing that task, from an energy source. Depending on its design, a power supply may obtain energy from:

  • Electrical energy transmission systems. Common examples of this include power supplies that convert AC line voltage to DC voltage.
  • Energy storage devices such as batteries and fuel cells.
  • Electromechanical systems such as generators and alternators.
  • Solar power.

A power supply may be implemented as a discrete, stand-alone device or as an integral device that is hardwired to its load. In the latter case, for example, low voltage DC power supplies are commonly integrated with their loads in devices such as computers and household electronics.

Constraints that commonly affect power supplies include:

  • The amount of voltage and current they can supply.
  • How long they can supply energy without needing some kind of refueling or recharging (applies to power supplies that employ portable energy sources).
  • How stable their output voltage or current is under varying load conditions.
  • Whether they provide continuous or pulsed energy.

Power supplies types

Power supplies for electronic devices can be broadly divided into linear and switching power supplies. The linear supply is usually a relatively simple design, but it becomes increasingly bulky and heavy for high-current equipment due to the need for large mains-frequency transformers and heat-sinked electronic regulation circuitry. Linear voltage regulators produce regulated output voltage by means of an active voltage divider that consumes energy, thus making efficiency low. A switched-mode supply of the same rating as a linear supply will be smaller, is usually more efficient, but will be more complex.

Battery

A battery is an alternative to a line-operated power supply;[1] it is independent of the availability of mains electricity, suitable for portable equipment and use in locations without mains power. A battery consists of several electrochemical cells connected in series to provide the voltage desired. Batteries may be primary (able to supply current when constructed, discarded when drained) or secondary (rechargeable; can be charged, used, and recharged many times)

The primary cell first used was the carbon-zinc dry cell.[1] It had a voltage of 1.5 volts; later battery types have been manufactured, when possible, to give the same voltage per cell. Carbon-zinc and related cells are still used, but the alkaline battery delivers more energy per unit weight and is widely used. The most commonly used battery voltages are 1.5 (1 cell) and 9V (6 cells).

Various technologies of rechargeable battery are used. Types most commonly used are NiMH, and lithium ion and variants.

DC power supply

A home-made linear power supply (used here to power amateur radio equipment)

An AC powered unregulated power supply usually uses a transformer to convert the voltage from the wall outlet (mains) to a different, nowadays usually lower, voltage. If it is used to produce DC, a rectifier is used to convert alternating voltage to a pulsating direct voltage, followed by a filter, comprising one or more capacitors, resistors, and sometimes inductors, to filter out (smooth) most of the pulsation. A small remaining unwanted alternating voltage component at mains or twice mains power frequency (depending upon whether half- or full-wave rectification is used)—ripple—is unavoidably superimposed on the direct output voltage.

For purposes such as charging batteries the ripple is not a problem, and the simplest unregulated mains-powered DC power supply circuit consists of a transformer driving a single diode in series with a resistor.

Before the introduction of solid-state electronics, equipment used valves (vacuum tubes) which required high voltages; power supplies used step-up transformers, rectifiers, and filters to generate one or more direct voltages of some hundreds of volts, and a low alternating voltage for filaments. Only the most advanced equipment used expensive and bulky regulated power supplies.

AC power supply

An AC power supply typically takes the voltage from a wall outlet (mains supply, often 230v in Europe) and lowers it to the desired voltage (eg 9vac). As well as lowering the voltage some filtering may take place. An example use for an AC power supply is powering certain guitar effects pedals (e.g. the Digitech Whammy pedal) although it is more common for effects pedals to require DC.

Linear regulated power supply

The voltage produced by an unregulated power supply will vary depending on the load and on variations in the AC supply voltage. For critical electronics applications a linear regulator may be used to set the voltage to a precise value, stabilized against fluctuations in input voltage and load. The regulator also greatly reduces the ripple and noise in the output direct current. Linear regulators often provide current limiting, protecting the power supply and attached circuit from overcurrent.

Adjustable linear power supplies are common laboratory and service shop test equipment, allowing the output voltage to be adjusted over a range. For example, a bench power supply used by circuit designers may be adjustable up to 30 volts and up to 5 amperes output. Some can be driven by an external signal, for example, for applications requiring a pulsed output.

AC/DC supply

Main article: AC/DC (electricity)

In the past, mains electricity was supplied as DC in some regions, AC in others. Transformers cannot be used for DC, but a simple, cheap unregulated power supply could run directly from either AC or DC mains without using a transformer. The power supply consisted of a rectifier and a filter capacitor. When operating from DC, the rectifier was essentially a conductor, having no effect; it was included to allow operation from AC or DC without modification.

Switched-mode power supply

Main article: Switched-mode power supply

A computer’s switched mode power supply unit.

A switched-mode power supply (SMPS) works on a different principle. AC input, usually at mains voltage, is rectified without the use of a mains transformer, to obtain a DC voltage. This voltage is then switched on and off at a high speed by electronic switching circuitry, which may then pass through a high-frequency, hence small, light, and cheap, transformer or inductor. The duty cycle of the output square wave increases as power output requirements increase. Switched-mode power supplies are always regulated. If the SMPS uses a properly-insulated high-frequency transformer, the output will be electrically isolated from the mains, essential for safety.

The input power slicing occurs at a very high speed (typically 10 kHz — 1 MHz). High frequency and high voltages in this first stage permit much smaller transformers and smoothing capacitors than in a power supply operating at mains frequency, as linear supplies do. After the transformer secondary, the AC is again rectified to DC. To keep output voltage constant, the power supply needs a sophisticated feedback controller to monitor current drawn by the load.

SMPSs often include safety features such as current limiting or a crowbar circuit to help protect the device and the user from harm.[2] In the event that an abnormal high-current power draw is detected, the switched-mode supply can assume this is a direct short and will shut itself down before damage is done. For decades PC power supplies have provided a power good signal to the motherboard whose absence prevents operation when abnormal supply voltages are present.

SMPSs have an absolute limit on their minimum current output.[3] They are only able to output above a certain power level and cannot function below that point. In a no-load condition the frequency of the power slicing circuit increases to great speed, causing the isolated transformer to act as a Tesla coil, causing damage due to the resulting very high voltage power spikes. Switched-mode supplies with protection circuits may briefly turn on but then shut down when no load has been detected. A very small low-power dummy load such as a ceramic power resistor or 10-watt light bulb can be attached to the supply to allow it to run with no primary load attached.

Power factor has become a recent issue of concern for computer manufacturers. Switched mode power supplies have traditionally been a source of power line harmonics and have a very poor power factor. Many computer power supplies built in the last few years now include power factor correction built right into the switched-mode supply, and may advertise the fact that they offer 1.0 power factor.

By slicing up the sinusoidal AC wave into very small discrete pieces, a portion of unused alternating current stays in the power line as very small spikes of power that cannot be utilized by AC motors and results in waste heating of power line transformers. Hundreds of switched mode power supplies in a building can result in poor power quality for other customers surrounding that building, and high electric bills for the company if they are billed according to their power factor in addition to the actual power used. Filtering capacitor banks may be needed on the building power mains to suppress and absorb these negative power factor effects[citation needed].

Programmable power supply

Programmable power supplies

Programmable power supplies allow for remote control of the output voltage through an analog input signal or a computer interface such as RS232 or GPIB. Variable properties include voltage, current, and frequency (for AC output units). These supplies are composed of a processor, voltage/current programming circuits, current shunt, and voltage/current read-back circuits. Additional features can include overcurrent, overvoltage, and short circuit protection, and temperature compensation. Programmable power supplies also come in a variety of forms including modular, board-mounted, wall-mounted, floor-mounted or bench top.

Programmable power supplies can furnish DC, AC, or AC with a DC offset. The AC output can be either single-phase or three-phase. Single-phase is generally used for low-voltage, while three-phase is more common for high-voltage power supplies.

Programmable power supplies are now used in many applications. Some examples include automated equipment testing, crystal growth monitoring, and differential thermal analysis.[4]

Uninterruptible power supply

Main article: Uninterruptible power supply

An uninterruptible power supply (UPS) takes its power from two or more sources simultaneously. It is usually powered directly from the AC mains, while simultaneously charging a storage battery. Should there be a dropout or failure of the mains, the battery instantly takes over so that the load never experiences an interruption. Such a scheme can supply power as long as the battery charge suffices, e.g., in a computer installation, giving the operator sufficient time to effect an orderly system shutdown without loss of data. Other UPS schemes may use an internal combustion engine or turbine to continuously supply power to a system in parallel with power coming from the AC . The engine-driven generators would normally be idling, but could come to full power in a matter of a few seconds in order to keep vital equipment running without interruption. Such a scheme might be found in hospitals or telephone central offices.

High-voltage power supply

High voltage refers to an output on the order of hundreds or thousands of volts. High-voltage supplies use a linear setup to produce an output voltage in this range.

Additional features available on high-voltage supplies can include the ability to reverse the output polarity along with the use of circuit breakers and special connectors intended to minimize arcing and accidental contact with human hands. Some supplies provide analog inputs (i.e. 0-10V) that can be used to control the output voltage, effectively turning them into high-voltage amplifiers albeit with very limited bandwidth.

Voltage multipliers

Voltage multipliers, as the name implies, are circuits designed to multiply the input voltage. The input voltage may be doubled (voltage doubler), tripled (voltage tripler), quadrupled (voltage quadrupler), etc. Voltage multipliers are also power converters. An AC input is converted to a higher DC output. These circuits allow high voltages to be obtained using a much lower voltage AC source.

Typically, voltage multipliers are composed of half-wave rectifiers, capacitors, and diodes. For example, a voltage tripler consists of three half-wave rectifiers, three capacitors, and three diodes (see Cockcroft Walton Multiplier). Full-wave rectifiers may be used in a different configuration to achieve even higher voltages. Also, both parallel and series configurations are available. For parallel multipliers, a higher voltage rating is required at each consecutive multiplication stage, but less capacitance is required. The voltage capability of the capacitor limits the maximum output voltage.

Voltage multipliers have many applications. For example, voltage multipliers can be found in everyday items like televisions and photocopiers. Even more applications can be found in the laboratory, such as cathode ray tubes, oscilloscopes, and photomultiplier tubes.[5][6]

Power supply applications

Computer power supply

Main article: Computer power supply

A modern computer power supply is a switch with on and off supply designed to convert 110-240 V AC power from the mains supply, to several output both positive (and historically negative) DC voltages in the range + 12V,-12V,+5V,+5VBs and +3.3V. The first generation of computers power supplies were linear devices, but as cost became a driving factor, and weight became important, switched mode supplies are almost universal.

The diverse collection of output voltages also have widely varying current draw requirements, which are difficult to all be supplied from the same switched-mode source. Consequently most modern computer power supplies actually consist of several different switched mode supplies, each producing just one voltage component and each able to vary its output based on component power requirements, and all are linked together to shut down as a group in the event of a fault condition.

Welding power supply

Main article: Welding power supply

Arc welding uses electricity to melt the surfaces of the metals in order to join them together through coalescence. The electricity is provided by a welding power supply, and can either be AC or DC. Arc welding typically requires high currents typically between 100 and 350 amps. Some types of welding can use as few as 10 amps, while some applications of spot welding employ currents as high as 60,000 amps for an extremely short time. Older welding power supplies consisted of transformers or engines driving generators. More recent supplies use semiconductors and microprocessors reducing their size and weight.

AC adapter

Switched mode mobile phone charger

Main article: AC adapter

A linear or switched-mode power supply (or in some cases just a transformer) that is built into the top of a plug is known as a “plug pack”, “plug-in adapter”, “adapter block”, “domestic mains adapter” or just “power adapter”. Slang terms include “wall wart” and “power brick”. They are even more diverse than their names; often with either the same kind of DC plug offering different voltage or polarity, or a different plug offering the same voltage. “Universal” adapters attempt to replace missing or damaged ones, using multiple plugs and selectors for different voltages and polarities. Replacement power supplies must match the voltage of, and supply at least as much current as, the original power supply.

The least expensive AC units consist solely of a small transformer, while DC adapters include a few additional diodes. Whether or not a load is connected to the power adapter, the transformer has a magnetic field continuously present and normally cannot be completely turned off unless unplugged.

Because they consume standby power, they are sometimes known as “electricity vampires” and may be plugged into a power strip to allow turning them off. Expensive switched-mode power supplies can cut off leaky electrolyte-capacitors, use powerless MOSFETs, and reduce their working frequency to get a gulp of energy once in a while to power, for example, a clock, which would otherwise need a battery.

Overload protection

Power supplies often include some type of overload protection that protects the power supply from load faults (e.g., short circuits) that might otherwise cause damage by overheating components or, in the worst case, electrical fire. Fuses and circuit breakers are two commonly used mechanisms for overload protection.[1]

Fuses

A fuse is a piece of wire, often in a casing that improves its electrical characteristics. If too much current flows, the wire becomes hot and melts. This effectively disconnects the power supply from its load, and the equipment stops working until the problem that caused the overload is identified and the fuse is replaced.

There are various types of fuses used in power supplies.

  • fast blow fuses cut the power as quick as they can
  • slow blow fuses tolerate more short term overload
  • wire link fuses are just an open piece of wire, and have poorer overload characteristics than glass and ceramic fuses

Some power supplies use a very thin wire link soldered in place as a fuse.

Circuit breakers

One benefit of using a circuit breaker as opposed to a fuse is that it can simply be reset instead of having to replace the blown fuse. A circuit breaker contains an element that heats, bends and triggers a spring which shuts the circuit down. Once the element cools, and the problem is identified the breaker can be reset and the power restored.

Thermal cutouts

Some PSUs use a thermal cutout buried in the transformer rather than a fuse. The advantage is it allows greater current to be drawn for limited time than the unit can supply continuously. Some such cutouts are self resetting, some are single use only.

Current limiting

Some supplies use current limiting instead of cutting off power if overloaded. The two types of current limiting used are electronic limiting and impedance limiting. The former is common on lab bench PSUs, the latter is common on supplies of less than 3 watts output.

A foldback current limiter reduces the output current to much less than the maximum non-fault current.

Power conversion

The term “power supply” is sometimes restricted to those devices that convert some other form of energy into electricity (such as solar power and fuel cells and generators). A more accurate term for devices that convert one form of electric power into another form (such as transformers and linear regulators) is power converter. The most common conversion is from AC to DC.

Mechanical power supplies

  • Flywheels coupled to electrical generators or alternators
  • Compulsators
  • Explosively pumped flux compression generators

Terminology

  • SCP – Short circuit protection
  • OPP – Overpower (overload) protection
  • OCP – Overcurrent protection
  • OTP – Overtemperature protection
  • OVP – Overvoltage protection
  • UVP – Undervoltage protection
  • UPS – Uninterruptable Power Supply
  • PSU – Power Supply Unit
  • SMPSU – Switch-Mode Power Supply Unit

http://creativecommons.org/licenses/by-sa/3.0/

Category : ATM Board Repair | Industrial Repair Group | Industrial Repair Service | Power Supply Repair | Talaris / DeLaRue & Delta ATM Power Supply Repair | Blog